فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها




گروه تخصصی











متن کامل


نویسندگان: 

darkhor parvaneh | PIRAYESH ISLAMIAN JALIL

اطلاعات دوره: 
  • سال: 

    2020
  • دوره: 

    7
  • شماره: 

    2
  • صفحات: 

    125-133
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    124
  • دانلود: 

    0
چکیده: 

In Single Photon Emission Computed Tomography (SPECT), collimator selection, optimization, and also geometric calibration have a major impact on the acquired image quality and also on an accurate detectability and diagnosis. The collimator optimization phenomena consider some parameters such as field of view, resolution, sensitivity, resolution at depth, septal thickness and penetration for a specific application task. While the parallel hole collimator is usually used in SPECT and planar imaging but due to the limited solid angle covered by the collimator, the system sensitivity and resolution were highly reduced. Meanwhile, other types of collimators such as pin-hole, multi-pin-hole, slant and slit-slat collimators were introduced with a trade-off between sensitivity and resolution. This article reviews improvements on collimators also by considering the geometry and geometric calibration methods for improving the image quality in Single Photon Emission Computed tomography.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 124

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 3
نشریه: 

Acta Medica Iranica

اطلاعات دوره: 
  • سال: 

    2011
  • دوره: 

    49
  • شماره: 

    1
  • صفحات: 

    13-17
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    359
  • دانلود: 

    0
چکیده: 

Anosmia following head trauma is relatively common and in many cases is persistent and irreversible. The ability to objectively measure such a decline in smelling, for both clinical and medicolegal goals, is very important. The aim of this study was to find results of brain Single Photon Emission Computed Tomography (SPECT) in anosmic subjects after closed head trauma. This case-control cross sectional study was conducted in a tertiary referral University Hospital. The brain perfusion state of nineteen anosmic patients and thirteen normal controls was evaluated by means of the SPECT with 99mtc- ECD infusionbefore and after olfactory stimulation. The orbitofiontal lobe of the brain was assumed as the region of interest and changes in perfusion of this area before and after the stimulations were compared in two groups. The mean of brain perfusion in controls before and after the stimulation was 8.26% 0±19% and 9.89%± 0.54%, respectively (P<0.0001). Among patients group, these quantities were 7.97%±1.05% and 8.49%± 1.5%, respectively (P<0.004). The difference between all the measures in cases and controls were statistically significant (P<0.0001). There were no differences in age and sex between two groups. The brain SPECT is an objective technique suitable for evaluating anosmia following the head trauma and it may be used with other diagnostic modalities.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 359

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1401
  • دوره: 

    40
  • شماره: 

    683
  • صفحات: 

    624-631
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    190
  • دانلود: 

    38
چکیده: 

مقدمه: تصویربرداری توموگرافی کامپیوتری با انتشار تک فوتون (Single Photon Emission Computed tomography) SPECT به طور گسترده در پزشکی هسته ای استفاده می شود. این روش غیر تهاجمی برای بررسی خون رسانی به عضله ی قلب و تشخیص بیماری های قلبی بسیار مفید است. برای افزایش دقت تشخیص، بهبود کیفیت تصاویر SPECT که به دلیل وجود نویز کاهش یافته است، ضروری است. هدف از این مطالعه، ارزیابی اثربخشی استفاده از فیلترهای Butterworth، Gaussian، Wiener با اندازه کرنل های 3‍, ‍, ×3 و 5×5، Wiener اصلاح شده ی میانه (MMWF) با اندازه ی کرنل های 3‍, ‍, ×3 و 5×5 برای افزایش کیفیت تصاویر SPECT پرفیوژن میوکارد با می باشد. روش ها: داده ها در این مطالعه که از نوع مقطعی-کاربردی می باشد، با استفاده از دستگاه SPECT/CT scanner Siemens symbia T2 dual head که با یک کولیماتور کم انرژی و با وضوح بالا (LEHR) نصب شده است، تهیه شد. کیفیت تصاویر SPECT پرفیوژن میوکارد 30 بیمار پس از اعمال فیلترهای ذکر شده بر روی آن ها با شاخص های نسبت سیگنال به نویز (Signal-to-noise ratio) SNR، پیک نسبت سیگنال به نویز (PSNR) و نسبت کنتراست به نویز (Contrast to noise ratios) CNR ارزیابی شد. یافته ها: فیلتر Wiener با کرنل 5×5 بالاترین مقادیر شاخص های SNR و CNR را کسب کرد که به ترتیب برابر با 69/0 ±,90/4 و 57/0 ±,65/2 می باشد. در حالی که دارای کم ترین مقدار PSNR با مقدار (dB) 13/3 ±,93/29 است. بالاترین PSNR مربوط به فیلتر Gaussian با مقدار (dB) 63/10 ±,09/50 می باشد. نتیجه گیری: نتایج این مطالعه نشان داد که فیلتر Wiener با کرنل 5×5 برای بهبود کیفیت تصاویر SPECT پرفیوژن میوکارد مورد مطالعه ی ما نسبت به فیلترهای دیگر عملکرد بهتری از خود نشان می دهد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 190

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 38 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1389
  • دوره: 

    7
  • شماره: 

    2 (پیاپی 27)
  • صفحات: 

    9-20
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    851
  • دانلود: 

    0
چکیده: 

مقدمه: داده های توزیع رادیودارو که در روش برش نگاری رایانه ای نشرتک فوتونی(SPECT) برای بازسازی تصویری بکاربرده می شوندتحت تاثیرعواملی از قبیل تضعیف وپراکندگی پرتوهای گاما، ساختار همخط ساز، شیوه پردازش داده ها، حرکت بیمار و نحوه تصفیه رادیودارواز اندام هدف دستخوش تغییراتی می شوند. اینگونه تغییرات، بازسازی دقیق تصویر SPECT را کاملا مشکل میسازند. شبیه سازی سیستم SPECT راهی را برای ارزیابی تاثیر این عوامل در کیفیت تصویرفراهم می کند.مواد و روشها: ابتدا از برنامه SIMIND مونت کارلو برای شبیه سازی سیستم SPECT زیمنس مدل E.CAM استفاده شد و تعیین صحت شبیه سازی ازطریق مقایسه پارامترهای عملکردی دو سیستم واقعی وشبیه سازی شده انجام گرفت.سپس این سیستم برای شبیه سازی اسکن های SPECT فانتوم های همگن و ناهمگن و کسلی همراه با تغییرات سخت افزاری دربخش های کریستال و روکش محافظ آشکارساز، مجموعه مواد پشت آشکارساز و همچنین همخط ساز LEGR بکاربرده شد. نتایج بدست آمده از این شبیه سازی ها با نتایج اسکن های سیستم بدون تغییرات سخت افزاری مورد مقایسه قرار گرفت. کیفیت تصویربا مقایسه شاخص تشابه ساختاری (SSIM)، کنتراست وتفکیک فضایی تصویر ارزیابی شد.نتایج: طیف های انرژی حاصل از دو سیستم واقعی و شبیه سازی شده، نواحی پیک طیفی مشابهی را نشان دادند. مقادیر پهنای طیف انرژی در نصف حداکثر ارتفاع (FWHM) برای سیستم های واقعی و شبیه سازی شده به ترتیب:13.58  و 13.92 کیلو الکترون ولت، همچنین تفکیک انرژی به ترتیب 9.61 و 9.95 درصد و حساسیت سیستم ها 85.11 85.39 به واحد cps/MBq بدست آمد. سیستم شبیه سازی شده با تغییرات سخت افزاری شامل یک کریستال آشکارساز از جنس NaI(Tl) به ضخامت 944/0 سانتیمتر، روکش آلومینیومی به ضخامت 24/0 سانتیمتر، لایه ای 4.5 سانتیمتری از پیرکس به عنوان ماده پشت کریستال و همخط ساز موازی از جنس آلیاژ سرب- تنگستن باضخامت 2.405 سانتیمتر پارامترهای عملکردی بهتری را درمقایسه با سیستم بدون تغییر ارایه داد.بحث و نتیجه گیری: درپژوهش حاضر سیستم SPECT زیمنس مدل E.CAM با کد SIMIND مونت کارلو شبیه سازی شد. نتایج حاصل از اسکن های سیستم شبیه سازی شده، توافق خوبی با نتایج تجربی نشان دادند. یافته ها مشخص نمود که تغییرات سخت افزاری اشاره شده در سیستم تصویربرداری می تواند در بهینه سازی پارامترهای عملکردی سیستم نقش موثری ایفا کند. اکنون این سیستم می تواند در انجام بررسی های تکمیلی بهینه سازی تصاویر پزشکی هسته ای مورد استفاده قرار داده شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 851

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    316
  • شماره: 

    -
  • صفحات: 

    0-0
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    35
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 35

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2011
  • دوره: 

    19
  • شماره: 

    1 (SERIAL NO. 35)
  • صفحات: 

    1-5
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    355
  • دانلود: 

    0
چکیده: 

Documented evidences available from both developed and developing countries reveal that the number of clinical imaging procedures and instruments have continued to increase over the past decades, confirming the increasing demand for these clinical imaging modalities. Accordingly, concerns about over-utilization and inappropriate use in imaging have been raised, and consequently medical authorities and clinicians who were slow to respond to spiraling costs of cardiac imaging years ago, now recognize the need to promote appropriate and cost-conscious use of imaging, mainly through the development of appropriateness criteria and guidelines, which are focused on eliminating unnecessary testing to decrease health care costs.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 355

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    2018
  • دوره: 

    26
  • شماره: 

    1 (SERIAL NUMBER 50)
  • صفحات: 

    22-29
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    224
  • دانلود: 

    0
چکیده: 

Introduction: Myocardial perfusion SPECT by 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-cardiac activities by Slit Slat collimation.Methods: The Siemens E.CAM gamma camera equipped with a Low Energy High Resolution (LEHR) collimator was simulated with the Simulating Medical Imaging Nuclear Detectors (SIMIND) Monte Carlo program. Following the verification of the simulation, a Slit Slat collimator was simulated for SPECT imaging of a NURBS-based Cardiac Torso (NCAT) phantom with different Slit angels ranged from 0 to 30 degrees. The reconstructed images were qualitatively assessed with blinded observer method by three nuclear medicine specialists.Results: The improved differentiation of the bowel activity from the cardiac was obtained by a Slit-Slat collimator with the Slit angle of 7 degree. While for gastric activity differentiation an angle of 15 degree for the Slit was useful.Conclusion: The results showed that Slit Slat collimation with 7 and 15 Slit angle provide a suitable differentiation of the bowel and gastric activities from the cardia, respectively.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 224

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نشریه: 

Iranian Heart Journal

اطلاعات دوره: 
  • سال: 

    2019
  • دوره: 

    20
  • شماره: 

    2
  • صفحات: 

    47-55
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    125
  • دانلود: 

    0
چکیده: 

Background: We sought to evaluate the association between hypertension (HTN) and left ventricular (LV) mechanical synchrony parameters derived via the phase analysis of gated Single-Photon Emission Computed tomography (GSPECT) myocardial perfusion imaging (MPI). Methods: Ninety-nine patients with no known coronary heart disease (CHD) who underwent GSPECT MPI and had normal resting and post-stress scan with a recent normal echocardiographic examination and a positive history of HTN were recruited. The gated images were analyzed by Cedar– Sinai’ s quantitative GSPECT. The global and regional LV mechanical synchrony indices— including phase histogram bandwidth (PHB), phase standard deviation (PSD), and entropy— were derived and compared with the results of the control group, which had previously been defined with the same protocol for a group of 100 patients with a low likelihood for CHD. Results: Comparisons between the study and control groups revealed that neither global nor regional wall-based indices for PHB, PSD, and entropy were significantly different between the 2 groups (P> 0. 05), whether or not HTN was accompanied by comorbid diabetes. Congruent with the control group, a significant difference was detected between the global LV phase parameters of the 2 genders (P<0. 05). Conclusions: HTN does not intrinsically have a significant impact on the mechanical synchrony indices of GSPECT MPI.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 125

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    43
  • شماره: 

    7
  • صفحات: 

    756-762
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    20
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 20

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نشریه: 

Iranian Heart Journal

اطلاعات دوره: 
  • سال: 

    2023
  • دوره: 

    24
  • شماره: 

    1
  • صفحات: 

    54-61
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    48
  • دانلود: 

    0
چکیده: 

Background: Phase analysis assesses left ventricular (LV) dyssynchrony from gated SinglePhoton Emission Computed tomography myocardial perfusion imaging (GSPECT-MPI). This study aimed to determine the impact of diabetes mellitus (DM) on phase parameters. Methods: The study population consisted of 121 diabetic patients with no history of coronary artery disease, hypertension, or dyslipidemia and no evidence of perfusion abnormalities or systolic dysfunction in GSPECT-MPI. The resting-state images of MPI were further analyzed using the Cedar–, Sinai quantitative GSPECT, and LV phase parameters, including phase histogram bandwidth (PHB), phase standard deviation (PSD), and entropy, were derived. The results were compared with the corresponding figures previously defined in a control group, consisting of 100 subjects with low likelihoods of coronary artery disease, in our center. Results: Significant differences existed in the derived values for PHB, PSD, and entropy between the DM and control groups concerning global whole LV synchrony (P>. 05). Likewise, PHB and PSD demonstrated no significant differences between the 2 groups regarding the regional wall-based analysis (P>. 05). In contrast, the entropy indices of the LV septum (P=. 019) and anterior wall (P=. 022) were significantly higher in the DM group. Conclusions: It appears that except for the regional wall-based entropy of the septum and the anterior wall, DM does not inherently impose any significant alterations on the mechanical synchrony indices of GSPECT-MPI. Consequently, the provided normal databases for GSPECT-MPI-derived synchrony parameters could be utilized in DM patients.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 48

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button